What you need?
- BlackBox and power supply
- Relay cable (3m) for connecting BlackBox
- Cable is provided by GlobalReader
- Auxilary contacts if needed
How to make installation?
- For counting pieces or worktime via contactor we need to find right place in the electrical cabinet. PS only use free contact on the contactor or relay in the electrical cabinet to prevent errors
- Use N.O or N.C contacts
- After connecting sensor and BlackBox contact GlobalReader support to verify the readings